Product Overview:

With 160 individual inflatable cells, the FlapCair LAL Cellular Support Mattress from Joerns Healthcare far exceeds the industry standard by providing maximum pressure relief and pain management to those requiring longer-term bed stays. Fully internal air circulation ensures true low air loss while individual inflation of cells allows for precise control over when and where pressure is applied. Low air loss has been shown to effecitvely alleviate pain, reduce secondary infections, and provide customized treatment. This system features three modes of operation: Autofirm, Pulsate, and Therapy. These modes automate the most common patient pressure needs, allowing caregivers more flexibility to assist the patient in other capacities.

Product Specifications / Dimensions


Specifiction LabelSpecification Value
Mattress Dimensions 36 W x 80 L x 8 D (89 cm W x 203 cm L x 20 cm D)
Mattress Weight 29.5 lbs
Maximum Weight Capacity 350 lbs (159 Kg)
Control Unit Dimensions 13.5 W x 11 H x 7.5 D (34 cm W x 28 cm H x 19 cm D)
Control Unit Weight 10 lbs (4.5 Kg)
Electrical Specifications 120 V AC / 60 Hz
Approvals UL Classified
Warranty 2 years on the mattress. and 1 year on the cover and electromachanical compenents (See Warranty PDF for details)

Product Options:

Choose an option from each section marked (Required), then click "Add Selections to Cart":
Choose FlapCair LAL Pressure Relief Mattress System (Required)
Choose FlapCair Mattress Accessories (Optional)
Choose Replacement or Individual FlapCair LAL Parts (Optional)
Delivery Options (Required)
Delivery Options Explained

More Information

The FlapCair LAL Cellular Support Mattress by Joerns provides the maximum in pressure relief and pain management for patients requiring longer-term bed stays. While the industry standard for therapeutic support mattresses is only 20 inflated cells, the FlapCair LAL features 160 cells. These extra cells help to achieve full weight distribution and precise pressure for increased treatment and preventative care against dangerous and costly secondary conditions and infections. Each cell can be individually adjusted to treat wounds or surgical sites and can be controlled by zone (head, seat, or foot), too.

There are three modes of automated operation: Autofirm, Pulsate, and Therapy. By activating these automated operational modes, caregivers achieve increased flexibility to assist the patient with other needs. The easy-to-use control unit features a panel lock that avoids accidental adjustments and is designed for durability with minimal noise.

The FlapCair LAL has a fully internalized air circulation system to minimize air loss, even with ambient temperature changes. It features a cell depth of 6-inches to ensure that patients are always fully supported. A lower 2-inch support barrier is built-in to ensure inflation and prevent bottoming out, even in the event of sudden power loss.

This system includes the CairRails risk management system, which possesses inflated barriers along each side that guard against accidents patient falls. Additionally, this system features low shear, low friction nylon microbial therapy pads that protect against the growth of mold, mildew, and odor-causing bacteria. These therapy pads are machine washable.

This unit includes the mattress and control unit with a hard-wired power cord. Please note that bed frames are sold separately.


FAQ For FlapCair LAL (Low Air Loss) Cellular Support Mattress by Joerns

? Have a question about this product? Click here to ask us!
What are the best bed sheets to use with this mattress?
Answer: The recommended linens for this bed are no linens. The therapy pad should cover the therapy cells at all times so there is no need for a bottom sheet.
My therapy surface is not inflating, what should I do?
Answer: First, check to make sure that the hose connection from the therapy mattress system is securely connected. Then ensure that the control unit is plugged into an AC outlet. After that check to see if the power is not on standby, if it is on standby press the power button. Lastly. ensure that all the air cells are connected to the internal mattress manifold. For additional assistance please look in the user manual.
How should this mattress be cleaned?
Answer: If there is no visible soilage, clean the mattress system with mild detergent and warm water. If you need to disinfect the mattress use detergent/disinfectants that are registered by the EPA as hospital disinfectants. Please see additional instructions for further instruction on cleaning and disinfection.

FlapCair LAL (Low Air Loss) Cellular Support Mattress by Joerns Pictures:

FlapCair LAL (Low Air Loss) Cellular Support Mattress by Joerns
FlapCair LAL (Low Air Loss) Cellular Support Mattress by Joerns
The FlapCair mattress has 160 individual inflated cells for maximum pressure control and comfort.
The FlapCair mattress has 160 individual inflated cells for maximum pressure control and comfort.
The FlapCair mattress control unit is easy to use, locks to avoid accidental setting changes, and is built to minimize sound.
The FlapCair mattress control unit is easy to use, locks to avoid accidental setting changes, and is built to minimize sound.
Front of control unit shown above
Front of control unit shown above
Optional CairRails shown above
Optional CairRails shown above